Home AEDs Did Not Reduce Post-MI Mortality


 

CHICAGO — Placing an automated external defibrillator in the homes of patients with a previous anterior wall MI did not reduce mortality in a large randomized, multicenter trial.

The primary end point of death from any cause was not significantly different between patients who were randomized to the control response of calling emergency medical services and performing CPR, and patients who were randomized to use of an automated external defibrillator (AED), followed by calling emergency services and performing CPR.

With a median follow-up of 37 months, 228 of the 3,506 (6.5%) patients in the control group died, compared with 222 of the 3,495 (6.4%) patients in the AED group (hazard ratio 0.97), principal investigator Dr. Gust H. Bardy and his associates reported at the annual meeting of the American College of Cardiology.

Of the 450 deaths in the Home Automated External Defibrillator Trial (HAT), cardiac death occurred in 129 patients in the control arm and in 138 patients in the AED group; noncardiac death occurred in 89 control patients and 81 AED patients; and tachyarrhythmia occurred in 84 control patients and 85 AED patients. Thirteen deaths could not be classified.

Patients enrolled in HAT were not candidates for implantation of a cardioverter-defibrillator. In addition, unlike standard care, they were advised about the risk of sudden cardiac arrest, said Dr. Bardy of the Seattle Institute for Cardiac Research. The patients' median age was 62 years, and their median left ventricular ejection fraction was 45%.

AEDs were used in 32 patients, of which 14 received an appropriate shock. Of those 14 patients, 9 died within 48 hours, 1 died 48 hours after shock was delivered, and only 4 (28.6%) survived to the study's end. There were no inappropriate shocks in the study, which was sponsored by the National Heart, Lung, and Blood Institute and performed at 178 clinical sites in seven countries. Of note, AEDs were used by neighbors or visitors in seven patients in cardiac arrest, and two of those patients survived long term, he said.

With the exception of diabetes, there was no significant interaction between AED use and any outcome with regard to age (65 years or older vs. younger than 65 years), gender, Q-wave versus non-Q-wave MI status, heart failure class, revascularization, or nationality (United States vs. all other countries).

The lack of benefit observed with home AED therapy in HAT is likely attributable to the lower than expected rate of overall mortality and sudden cardiac arrest, Dr. Bardy explained. This probably reflects the participants' excellent adherence to pharmacologic therapies, such as β-blockers, ACE inhibitors, and statins; their high rate of previous revascularization (72%); and their increased awareness of the risk of sudden cardiac death.

In addition, the study was based on the assumption that patients would be at home and in the presence of their spouses or partners more than 50% of the time. In reality, only 117 events occurred at home, and only 58 of those were witnessed. About one-third of deaths started at night, and many of the daytime patients were in asystole, said Dr. Bardy, who disclosed relationships with Cameron Health Inc.

Dr. Bruce D. Lindsay, a discussant and director of cardiac electrophysiology at Washington University, St. Louis, asked Dr. Bardy to speculate on whether there would be a benefit in recommending home AEDs for higher-risk MI patients during the 3-month period recommended in the guidelines before primary prevention therapy can begin. Dr. Bardy responded that there is no downside to the device and that all MI patients should be made aware of the risk of sudden cardiac arrest and CPR techniques.

“They need to know that this is only one small part of their overall care post MI,” he said. Based on the data, however, he said he couldn't vigorously recommend that high-risk patients buy a home AED. “But I wouldn't argue against it, if someone wanted to do it.”

Anecdotally, families were happy to have a home AED, he said, even if the patient ultimately died. Survivors were “ebullient” that it was available.

In two cases, the device advised the spouse or partner not to shock, and the patient died. In one case, the patient inadvertently turned off the device.

Recommended Reading

Heart Disease Risk Higher in Cancer Survivors
MDedge Internal Medicine
Some Cancers Need Prolonged, High-Dose VTE Prophylaxis
MDedge Internal Medicine
Early Medications Cut Postablation Arrhythmias
MDedge Internal Medicine
Moderate Fitness Levels Protect Against Stroke
MDedge Internal Medicine
Excessive Daytime Sleepiness Linked With Higher Stroke Risk
MDedge Internal Medicine
Impaired Fasting Glucose Boosts Stroke Risk in Asymptomatic Men
MDedge Internal Medicine
OSA Related to Hypertension and Heart Failure : The more severe the sleep apnea, the higher a patient's nocturnal and daytime blood pressure.
MDedge Internal Medicine
Sleep Apnea Disrupts Classic Circadian Pattern of Sudden Cardiac Death
MDedge Internal Medicine
Too Much, Too Little Sleep Doubles Mortality
MDedge Internal Medicine
Device Uses Infrared Light to Assess Plaques
MDedge Internal Medicine