Tips

Novel Intraoperative Technique to Visualize the Lower Cervical Spine: A Case Series

Author and Disclosure Information

 

References

Lack of visualization can lead to aborted surgeries or, potentially, surgery at the wrong level.3 A 2008 American Academy of Neurological Surgeons survey indicated that 50% of spine surgeons had performed a wrong-level surgery at least once in their career, and the cervical spine accounted for 21% of all incorrect-level spine surgeries.7 Intraoperative factors reported during cases of wrong-level spinal surgeries included misinterpretation of intraoperative imaging, no intraoperative imaging, and unusual anatomy or physical characteristics.8 Such complications can lead to revision surgery and other significant morbidities for the patient.

In most patients, fluoroscopy allows confirmation of the correct level before disc incision.3 However, operating at a lower cervical level in a patient with a short neck or prominent shoulders poses a significant problem.3 A case report from Singh and colleagues9 described a modified intraoperative fluoroscopic view for spinal level localization at cervicothoracic levels. Their method focuses on identifying the bony lamina and using them as landmarks to count spinal levels, whereas our 30º–30º oblique image is useful for confirmation of adequate hardware placement during anterior cervical spinal fusions. Often, the initial localization of cervical vertebral levels can be achieved with a standard lateral radiograph. We recognized the utility of the 30º–30º oblique view when we were attempting to visualize the inferior aspect of the plate and inferior screw placement.

In patients with stout necks, a lateral radiograph may show only visualization down to C4 or C5.3 Even with applying traction to the arms or taping the shoulders down, it can be impossible to visualize C6, C7, or T1 because the shoulder bones and muscles obstruct the image.3 Using a 30º–30º oblique view, we were able to obtain adequate visualization and assess the accurate placement of hardware.

Conclusion

A 30º oblique view from horizontal and 30º cephalad from neutral radiograph can be used intraoperatively in patients with challenging anatomy to identify placement of hardware at the correct vertebral level in the lower cervical spine. It is a noninvasive technique that can help reduce the risk of wrong-site surgeries without prolonging operation time. This technique describes an alternative to the lateral radiograph and provides a solution to the difficult problem of intraoperative imaging of the mid- to lower cervical spine in 2 adequate planes.

Pages

Recommended Reading

Excision of Symptomatic Spinous Process Nonunion in Adolescent Athletes
MDedge Surgery
Medicaid Insurance Is Associated With Larger Curves in Patients Who Require Scoliosis Surgery
MDedge Surgery
Posterior Reversible Encephalopathy Syndrome: Temporary Visual Loss After Spinal Deformity Surgery
MDedge Surgery
Surgical Management of Gorham-Stout Disease of the Pelvis Refractory to Medical and Radiation Therapy
MDedge Surgery
Nonconsecutive Pars Interarticularis Defects
MDedge Surgery
PROMIS physical function domain outperforms in cervical spine patients
MDedge Surgery
Study characterizes injury risk in cervical myelopathy patients
MDedge Surgery
Functional dependence linked to risk of complications after spine surgery
MDedge Surgery
SF-6D best quality of life measure in cervical spine patients
MDedge Surgery
Long spine fusions can give patients improved quality of life
MDedge Surgery