Physician Resources

Newly Available, Newly Approved

Hip-Bearing System

DePuy Orthopaedics, Inc., has announced a new option for restoring hip mobility in patients who require total hip replacement: the Pinnacle® Acetabluar Cup System Ultamet® XL hip bearing. This modular system provides advanced technology for recreating the natural ball-and-socket joint of the hip to help increase joint stability, range of motion, and longevity of the implant.1,2

The Ultamet XL metal-on-metal bearing is used with DePuy’s exclusive Pinnacle Acetabular Cup System, providing surgeons with the option of choosing a polyethylene or metal insert for use with the same outer titanium cup that replaces the socket of the natural hip.

DePuy Orthopaedics lists the following as key benefits:

  • Greater range of motion and stability. Ultamet XL bearings offer up to 159° range of motion and 20 mm of jump distance (compared with 28- and 36-mm Ultamet bearings).
  • Proven technology. The latest data presented at the 2007 AAOS annual meeting show that the Pinnacle Acetabular Cup System has demonstrated 99.9% survivorship at 5 years.3
  • Significant wear reduction. In a recent wear-simulator study, 44-mm Ultamet XL bearings reduced early wear (run-in wear) by 92% compared with traditional metal-on-metal bearings.4
  • Optimized bone preservation. By maximizing the size of the femoral head in relation to the outer diameter of the acetabular shell, Ultamet® XL bearings allow for enhanced stability while preserving acetabular bone.

For more information, contact

DePuy Orthopedics
700 Orthopaedic Drive
Warsaw, Indiana 46581
Phone (800) 366-8143
www.depuyorthopedics.com


References

  1. Data on file at DePuy Orthopaedics, Inc.
  2. Engh A., et al. A randomized prospective evaluation of outcomes after total hip arthroplasty using cross-linked Marathon and non—cross-linked Enduron polyethylene liners. J Arthroplasty. 2006; 21(6; suppl. 2).
  3. Kindsfater K, Barrett W, Dowd J, Southworth C, Cassell M. Poster #P077. Midterm survival of the Pinnacle Multi- Liner Acetabular Cup in a prospective multi-center study. 2007 AAOS Annual Meeting.
  4. Data on file at DePuy Orthopaedics, Inc.

Knotless Implant System

ArthroCare® Corp. announced today it has received 510(k) clearance from the U.S. Food and Drug Administration to market its Magnum PI Knotless Implant System, which utilizes implants made of polyetheretherketone (PEEK) for the attachment of soft tissue to bone.

The Magnum PI Knotless Implant System provides surgeons who prefer non-metallic anchors with a r


 

Recommended Reading

Bilateral Discoid Medial Menisci of the Knee
MDedge Surgery
Patient Survey of Weight-Bearing and Physical Activity After In Situ Pinning for Slipped Capital Femoral Epiphysis
MDedge Surgery
12-Year-Old Boy With Left Knee Pain
MDedge Surgery
Tape Blisters Following Hip Surgery: Can They Be Eliminated Completely?
MDedge Surgery
Tibial Tubercle Fracture With Avulsion of the Patellar Ligament: A Case Report
MDedge Surgery
Treatment of Radiation-Induced Soft-Tissue Fibrosis and Concomitant Acetabular Osteonecrosis: A Case Report
MDedge Surgery
Factors Associated With Thromboprophylaxis for Orthopedic Patients and Their Impact on Outcome
MDedge Surgery
The Glenoid Center Point: A Magnetic Resonance Imaging Study of Normal Scapular Anatomy
MDedge Surgery
Accuracy of Injection Into the Basal Joint of the Thumb
MDedge Surgery
Newly Available, Newly Approved
MDedge Surgery