Latest News

PVC phlebitis rates varied widely, depending on assessment tool


 

FROM LANCET HAEMATOLOGY

Rates of phlebitis associated with peripheral venous catheters (PVC) ranged from less than 1% to 34% depending on which assessment tool researchers used in a large cross-sectional study.

Rates also varied within individual instruments because they included several possible case definitions, Katarina Göransson, PhD, and her associates reported in Lancet Haematology. “We find it concerning that our study shows variation of the proportion of PVCs causing phlebitis both within and across the instruments investigated,” they wrote. “How to best measure phlebitis outcomes is still unclear, since no universally accepted instrument exists that has had rigorous testing. From a work environment and patient safety perspective, clinical staff engaged in PVC management should be aware of the absence of adequately validated instruments for phlebitis assessment.”

There are many tools to measure PVC-related phlebitis, but no consensus on which to use, and past studies have reported rates of anywhere from 2% to 62%. Hypothesizing that instrument variability contributed to this discrepancy, the researchers tested 17 instruments in 1,032 patients who had 1,175 PVCs placed at 12 inpatient units in Sweden. Eight tools used clinical definitions, seven used severity rating systems, and two used scoring systems (Lancet Haematol. 2017 doi: 10.1016/S2352-3026[17]30122-9).

Rates of PVC-induced phlebitis reached 12% (137 cases) when the researchers used case definition tools, up to 31% when they used scoring systems (P less than .0001), and up to 34% when they used severity rating systems (P less than .0001, compared with the 12% rate). “The proportion within instruments ranged from less than 1% to 28%,” they added. “We [also] identified face validity issues, such as use of indistinct or complex measurements and inconsistent measurements or definitions.”

The investigators did not perform a systematic review to identify these instruments, and they did not necessarily use the most recent versions, they noted. Nevertheless, the findings have direct implications for hospital quality control measures, which require using a single validated instrument over time to generate meaningful results, they said. Hence, the investigators recommended developing a joint research program to develop reliable measures of PVC-related adverse events and better support clinicians who are trying to decide whether to remove PVCs.

The investigators reported having no funding sources and no competing interests.

Recommended Reading

Aspirin triples major bleeding risk after age 75 years
MDedge Cardiology
FDA approves betrixaban for VTE prophylaxis
MDedge Cardiology
Herpes zoster raises risk of stroke, MI
MDedge Cardiology
VIDEO: Meta-analysis favors anticoagulation for patients with cirrhosis and portal vein thrombosis
MDedge Cardiology
Bad news keeps piling up for Absorb coronary scaffold
MDedge Cardiology
Amplatzer devices outperform oral anticoagulation in atrial fib
MDedge Cardiology
Idarucizumab reversed dabigatran completely and rapidly in study
MDedge Cardiology
Watchman device for AF patients ineligible for oral anticoagulation gains support from 1-year registry outcomes
MDedge Cardiology
Stopping statins after stroke may up recurrent stroke risk
MDedge Cardiology
New findings from first all-female TAVR registry
MDedge Cardiology