Conference Coverage

Simple risk assessment predicts post-PCI ischemic events


 

They were also significantly more likely to have a patient-oriented composite outcome, defined as all-cause death, any myocardial infarction, or any revascularization (HR, 1.44; 95% CI, 1.28-1.63; P < .001).

There was also a significantly higher risk for cardiac death in HIR than in non-HIR patients (HR, 1.95; 95% CI, 1.16-3.29; P = .012).

However, there was no significant association between HIR status and clinically relevant bleeding (HR, 0.84; 95% CI, 0.66-1.06; P = .143).

When the researchers looked at individual ischemic risk features, they found that, on fully adjusted analyses, only two were independent predictors of target vessel failure and the patient-oriented composite outcome.

Having at least three stents implanted was significantly associated with target vessel failure (HR, 1.36; 95% CI, 1.02-1.80; P = .038), and borderline significantly associated with the patient oriented composite outcome (HR, 1.23; 95% CI, 1.00-1.53; P = .056).

Diffuse multivessel disease, especially in diabetic patients, was significantly associated with both target vessel failure (HR, 1.24; 95% CI, 1.02-1.51; P = .035) and with the patient-oriented composite outcome (HR, 1.20; 95% CI, 1.04-1.39; P = .012).

Neither risk feature was significantly associated with clinically relevant bleeding, Dr. Wang noted.

Stratifying the patients by HBR status, the team found that rates of target vessel failure, the patient-oriented composite outcome, cardiac death, myocardial infarction, and definite/probable stent thrombosis were higher in patients with both HIR and HBR than those with neither HIR nor HBR (P < .001).

Further stratifying patients by PRECISE-ADAPT scores – 10 or less indicating very low risk, 11-17 indicating low risk, 18-24 indicating moderate risk, and at least 25 indicating high risk – showed that HIR features had a consistent effect on ischemic and bleeding outcomes, regardless of bleeding risk.

No funding declared. No relevant financial relationships declared.

A version of this article first appeared on Medscape.com.

Pages

Recommended Reading

SAFE-PAD: Endovascular paclitaxel-coated devices exonerated in real-world analysis
MDedge Cardiology
Early aspirin withdrawal after PCI: More benefit for women?
MDedge Cardiology
Benefit from cooling temps for cardiac arrest does not differ in randomized trial
MDedge Cardiology
Full 2-year follow-up vindicates EVOLUT Low-Risk TAVR data
MDedge Cardiology
Single subcutaneous shot offers fast, potent platelet inhibition in STEMI
MDedge Cardiology
PASCAL mitral valve repair shines at 2 years in CLASP
MDedge Cardiology
Medtronic yanks Heartware VAD, calls for halt to new implants
MDedge Cardiology
Revised dispatch system boosts bystander CPR in those with limited English
MDedge Cardiology
Evidence builds for iPhone 12 interference with cardiac devices
MDedge Cardiology
First risk score to predict bleeding risk after TAVR
MDedge Cardiology