Drug-Coated Balloon Cuts Restenosis


 

CHICAGO — A coronary-angioplasty balloon coated with paclitaxel produced substantially better outcomes than a bare balloon during 1 year of follow-up in a pair of randomized studies with a total of about 100 patients.

This initial clinical experience showed that inhibition of restenosis “does not require stenting or sustained drug release,” Dr. Bruno Scheller said at the annual scientific sessions of the American Heart Association.

“This is a promising technology that appears to be simple, quick, and inexpensive,” but it needs testing in many more patients and at multiple centers, said Dr. Debabrata Mukherjee, associate director of the cardiac catheterization laboratory at the University of Kentucky in Lexington.

The Treatment of In-Stent Restenosis by Paclitaxel-Coated Balloon Catheters (PACCOCATH ISR) I and II studies both used balloon catheters coated with 3 mcg paclitaxel/mm

All patients had a restenotic lesion in a stented coronary artery and stable or unstable angina or an abnormal functional study. Lesions lengths had to be less than 30 mm. The patients' average age was 66.

Repeat angiographies after 6 months were available for 96 patients (89%) and showed an average in-segment, late luminal loss of 0.11 mm in the arteries treated with a drug-coated balloon and 0.84 mm in the control arteries, a statistically significant difference in the study's primary end point, reported Dr. Scheller, a cardiologist at the Saarland University Hospital in Homburg/Saar, Germany.

The binary restenosis rate was 6% in patients treated with paclitaxel, and 49% in those who had no drug treatment, also a significant difference. After 6 months the overall rate of major adverse cardiac events was 9% in the drug-treated patients and 39% in the control arm, mostly driven by a large difference in the rate of target lesion revascularization. After 12 months, the adverse cardiac event rate was 10% in the paclitaxel-treated patients and 40% in angioplasty-alone patients. After 18 months' follow-up, the adverse event rates were 10% with paclitaxel and 45% without.

Results for the 52 patients enrolled in PACCAOCATH ISR I were published shortly after Dr. Scheller's report at the meeting (N. Engl. J. Med. 2006;355:2113–24). Results for the combined study group of 108 patients were reported only at the meeting. Study II included patients with more complex lesions than in study I.

The paclitaxel-coated balloon catheter will soon be tested on de novo stenoses in small-diameter coronary arteries, at bifurcations, in tortuous coronaries, and in peripheral arteries, Dr. Scheller said.

Recommended Reading

Speedier ECGs Don't Affect Time To Reperfusion
MDedge Cardiology
Tool Kit for Faster D2B Times Involves Simple Changes
MDedge Cardiology
Transferring Patients for Angioplasty Can Be Quick, Safe
MDedge Cardiology
Less Bleeding With Bivalirudin in PCI
MDedge Cardiology
Low-Permeability Stent Reduces AAA Volume, Diameter at One Year
MDedge Cardiology
Sirolimus Stents at 9 Months Safer in Long Lesions
MDedge Cardiology
Atrial Natriuretic Peptide Reduces Infarct Size
MDedge Cardiology
High LVEF Hikes Risk in Older Women With ACS
MDedge Cardiology
Bosentan Safe, Effective in Children With PAH
MDedge Cardiology
Infant Age, Sex Tied to Mortality After Heart Repair
MDedge Cardiology