LVAD Plus Remodeling Drugs Can Reverse Severe Heart Failure


 

Severe heart failure can be reversed in some cases by using a left ventricular assist device to temporarily “unload” the myocardium plus a drug regimen to promote reverse remodeling, reported Dr. Emma J. Birks of the Royal Brompton and Harefield (England) National Health Service Trust and her associates.

In a study of 15 patients who received this treatment for nonischemic cardiomyopathy, 11 recovered sufficiently after a mean of 320 days to qualify for removal of the device. Ten of them survived with marked improvement that has persisted for over 4 years, the researchers said.

Following LVAD implantation, the patients received an ACE inhibitor (lisinopril), angiotensin-receptor blocker (losartan), a nonselective β-blocker (carvedilol), and an aldosterone antagonist (spironolactone) to enhance reverse remodeling. After maximal regression in the left ventricular end-diastolic diameter was achieved, the nonselective β-blocker was replaced with a selective β1-blocker together with clenbuterol, a selective β2-agonist, to prevent myocardial atrophy.

Eleven patients showed significant clinical improvement accompanied by marked functional changes in the myocardium and improved hemodynamics, exercise capacity, and quality of life. Ten (75%) fully recovered after the device was removed (N. Engl. J. Med. 2006;355:1873–84).

This study was supported in part by Thoratec, manufacturer of the HeartMate LVAD.

Recommended Reading

NT-proBNP Testing Cut Time to Heart Failure Dx
MDedge Cardiology
Treat Anemia to Improve Outcomes in Heart Failure Patients
MDedge Cardiology
Primary Care Docs Lag In Quality of HF Care
MDedge Cardiology
All Heart Failure Patients Should Be Screened for Sleep Apnea, Expert Says
MDedge Cardiology
Simple Screening Tool Detects Sleep Apnea in Heart Patients
MDedge Cardiology
Maximize Cardiac Meds to Treat Concomitant Sleep Apnea
MDedge Cardiology
Perindopril May Improve Diastolic Heart Failure
MDedge Cardiology
ACE Inhibitor Plus ARB Increases Risk, Not Benefit
MDedge Cardiology
Set Pacemaker Rate Below 90 In Heart Failure Patients
MDedge Cardiology
Patients Overestimate Their ICD Survival Gain
MDedge Cardiology