News

Radiation exposure in children with heart disease highest for transplants


 

FROM CIRCULATION

Children with heart disease are cumulatively exposed to relatively low levels of ionizing radiation from imaging procedures – less than the average annual background exposure in the United States – although those who have undergone more complex procedures such as heart transplants or cardiac catheterization experience significantly greater exposure, a retrospective cohort study has found.

Dr. Jason N. Johnson, a pediatric cardiologist at Duke University Medical Center, Durham, N.C., and his colleagues showed that the estimated lifetime attributable risk of cancer above baseline ranged from 6 cases per 100,000 exposed for children with atrial septal defect, to 1,677 per 100,000 exposed for cardiac transplant, with a median of 65 cases per 100,000 across surgical cohorts.

While conventional radiographic examination accounted for 92% of the total examinations, it accounted for only 8% of the cumulative effective dose, compared with cardiac catheterization, which represented 1.5% of all examinations but accounted for 60% of the total radiation exposure, according to a study published online June 9 in Circulation.

The study of 337 children aged 6 years or younger exposed to more than 13,000 radiation examinations found the lifetime attributable risk of cancer was nearly double in females versus males, mostly because of increased breast and thyroid cancer risk (Circulation 2014 June 9 [doi:10.1161/CIRCULATIONAHA.113.005425]).

The study was funded by grants from the National Institutes of Health and the Mend a Heart Foundation. One author reported receiving support from the U.S. Nuclear Regulatory Commission, the U.S. Department of Energy, and Duke University.

Recommended Reading

Pre-Anthracycline-Based Chemo Cardiac Imaging Questioned
MDedge Hematology and Oncology
Use of Ultrasound Expands Across Surgical Specialties
MDedge Hematology and Oncology
Diagnostic Imaging on the Rise Even in 'Accountable' HMOs
MDedge Hematology and Oncology
2-D Echo Is Inadequate Cardiomyopathy Screen in Childhood Cancer Survivors
MDedge Hematology and Oncology
Apps Proliferate Amid Concerns About Medical Use
MDedge Hematology and Oncology
Medicare Imaging Payments Fell 21% Since 2006
MDedge Hematology and Oncology
Two-Step Rule Sizes Up CT Pleural Effusions
MDedge Hematology and Oncology
Estimated 4,870 future cancers induced by pediatric CT annually
MDedge Hematology and Oncology
CT, CEA alone or combined better than nothing to detect colon cancer recurrence
MDedge Hematology and Oncology
Imaging procedure costs higher in the United States
MDedge Hematology and Oncology