Original Research

Effect of Distal Stem Geometry on Interface Motion in Uncemented Revision Total Hip Prostheses

Author and Disclosure Information

In this study, we compared differences in motion at the bone-prosthesis interface in femora in which a fluted, tapered, or cylindrical distal stem design had been implanted in a revision total hip arthroplasty model.

Paired, fresh-frozen, cadaveric femora underwent resection of the proximal femur to simulate the proximal femoral bone loss often present during revision total hip arthroplasty and implantation with either a fluted, tapered stem or a clinically proven cylindrical stem. Specimens were then preloaded and subjected to a synchronous axial and torsional load with continuous monitoring of axial displacement and rotation.

For the fluted, tapered stem, mean axial and rotational displacements were 13.33 μm and 9.81 μm, respectively, compared with 18.37 μm and 13.40 μm for the cylindrical stem (both Ps<.05). Therefore, the fluted, tapered stem design that was tested demonstrated superior initial biomechanical stability compared with that of the clinically proven cylindrical design tested. However, both stems demonstrated motion below the threshold necessary for bony ingrowth. Knowledge of the initial biomechanical properties of different stem designs may assist the revision joint surgeon in choosing the optimal prosthesis for implantation.


 

Recommended Reading

Characterization of a Consistent Radiographic Finding in Chronic Anterior Cruciate Ligament Deficiency: The Posteromedial Osteophyte
MDedge Surgery
The Effect of Obesity on Quality-of-Life Improvement After Total Knee Arthroplasty
MDedge Surgery
Concurrent Opening Wedge Osteotomy and Total Knee Replacement in a Patient With Posttraumatic Arthritis and a Varus Tibial Malunion
MDedge Surgery
Newly Available, Newly Approved
MDedge Surgery
Tibial Fracture After Total Knee Arthroplasty Treated With Retrograde Intramedullary Fixation
MDedge Surgery
A Comprehensive Approach to Outpatient Total Hip Arthroplasty
MDedge Surgery
Minimally Invasive Total Knee Arthroplasty: Past, Present, and Future
MDedge Surgery
The Impact of Smart Tools on Total Knee Arthroplasty
MDedge Surgery
Rationale for Thromboprophylaxis in Lower Joint Arthroplasty
MDedge Surgery
Aspirin Prophylaxis for Thromboembolic Disease After Total Joint Arthroplasty
MDedge Surgery